The LUN.target_id parameter points to a NVMe Namespace which starts from 1 and not 0. Fix the document to reflect the same while addressing a nvme device in the boot parameters
2.1 KiB
Name
Boot Device Addressing - addressing the correct boot device to use.
Synopsis
Serenity's kernel can select the boot device at boot time, based on the root
boot parameter.
This functionality is used to control which boot device is selected to be used for all further boot process operations.
Description
The kernel root
boot parameter takes the form of root={value}
, where the ={value}
trailer can be set to specific prefixes to indicate the boot device preference.
Addressing options
The user can choose to use addressing based on synthetic unix concepts:
block0:0
This is especially useful in static hardware setups, so the user can choose to use
either a raw StorageDevice
or partition block device. The 0,0
selection is the MAJOR,MINOR
numbers of the device.
However, when there's knowledge of the hardware arrangement of raw StorageDevice
s,
it could be valuable to use addressing based on hardware-relative interface-specific "location"
to address raw StorageDevice
s:
ata0:0:0 [First ATA controller, ATA first primary channel, master device]
nvme0:1:0 [First NVMe Controller, First NVMe Namespace, Not Applicable]
ramdisk0 [First Ramdisk]
When the logical arrangement is known, using (absolute) LUNs is the easiest option as it doesn't rely on using unix device numbers or hardware-relative location:
lun0:0:0 - first device on the first channel of the first controller to be enumerated
Note on selecting partitions from raw StorageDevice
s
All the addressing options above support selecting a partition device, given that
the selected device is a StorageDevice
and not a DiskPartition
device:
nvme0;part0
lun0:0:0;part0
The only exception to this is when choosing a BlockDevice
. As such,
trying to specify block0:0;part0
, for example, will lead to a kernel panic,
as an invalid boot device parameter.
Selecting a specific partition based on known GUID
For GPT partitions, passing PARTUUID:
and the GUID of the partition can be used
to select a GPT partition. Although it could be slower to find the corresponding
partition, it is the safest option available for persistent storage.