daemon/logger/loggertest/logreader.go:58:43: empty-lines: extra empty line at the end of a block (revive)
daemon/logger/ring_test.go:119:34: empty-lines: extra empty line at the end of a block (revive)
daemon/logger/adapter_test.go:37:12: empty-lines: extra empty line at the end of a block (revive)
daemon/logger/adapter_test.go:41:44: empty-lines: extra empty line at the end of a block (revive)
daemon/logger/adapter_test.go:170:9: empty-lines: extra empty line at the end of a block (revive)
daemon/logger/loggerutils/sharedtemp_test.go:152:43: empty-lines: extra empty line at the end of a block (revive)
daemon/logger/loggerutils/sharedtemp.go:124:117: empty-lines: extra empty line at the end of a block (revive)
daemon/logger/syslog/syslog.go:249:87: empty-lines: extra empty line at the end of a block (revive)
Signed-off-by: Sebastiaan van Stijn <github@gone.nl>
Some packages were using `logrus.Fatal()` in init functions (which logs the error,
and (by default) calls `os.Exit(1)` after logging).
Given that logrus formatting and outputs have not yet been configured during the
initialization stage, it does not provide much benefits over a plain `panic()`.
This patch replaces some instances of `logrus.Fatal()` with `panic()`, which has
the added benefits of not introducing logrus as a dependency in some of these
packages, and also produces a stacktrace, which could help locating the problem
in the unlikely event an `init()` fails.
Before this change, an error would look like:
$ dockerd
FATA[0000] something bad happened
After this change, the same error looks like:
$ dockerd
panic: something bad happened
goroutine 1 [running]:
github.com/docker/docker/daemon/logger/awslogs.init.0()
/go/src/github.com/docker/docker/daemon/logger/awslogs/cloudwatchlogs.go:128 +0x89
Signed-off-by: Sebastiaan van Stijn <github@gone.nl>
pkg/urlutil (despite its poorly chosen name) is not really intended as a generic
utility to handle URLs, and should only be used by the builder to handle (remote)
build contexts.
This patch:
- removes a redundant use of urlutil.IsTransportURL(); instead adding some code
to check if the given scheme (protocol) is supported.
- define a `defaultPort` const for the default port.
- use `net.JoinHostPort()` instead of string concatenating, to account for possible
issues with IPv6 addresses.
- renames a variable that collided with an imported package.
- improves test coverage, and moves an integration test.
Signed-off-by: Sebastiaan van Stijn <github@gone.nl>
Adds the following validations to the syslog logger test:
1. Only supported options are valid
2. Log option syslog-address has to be a valid URI
3. Log option syslog-address if is file has to exist
4. Log option syslog-address if udp/tcp scheme, default to port 513
5. Log-option syslog-facility has to be a valid facility
6. Log-option syslog-format has to be a valid format
Signed-off-by: Joao Trindade <trindade.joao@gmail.com>
Signed-off-by: Sebastiaan van Stijn <github@gone.nl>
This fix tries to address the issue raised in 38258
where current RFC5424 sys log format does not zero pad
the time (trailing zeros are removed)
This fix apply the patch to fix the issue. This fix fixes 38258.
Signed-off-by: Yong Tang <yong.tang.github@outlook.com>
logger.PutMessage, added in #28762 (v17.04.0-ce), clears msg.Source. So journald
and syslog were treating stderr messages as if they were stdout.
Signed-off-by: David Glasser <glasser@davidglasser.net>
RFC 5424 (https://tools.ietf.org/html/rfc5424#section-6.2) requires that
STRUCTURED-DATA be present, either as NILVALUE (-) or as one or more
SD-ELEMENT items. Because Docker doesn't ever create any SD-ELEMENT items,
the format should output the NILVALUE instead. This resolves parsing issues
in various RFC 5424-compliant syslog servers.
Signed-off-by: Mark Parker <godefroi@gmail.com>
This reduces allocs and bytes used per log entry significantly as well
as some improvement to time per log operation.
Each log driver, however, must put messages back in the pool once they
are finished with the message.
Signed-off-by: Brian Goff <cpuguy83@gmail.com>
This fix tries to address the issue raised in #22358 where syslog's
message tag always starts with `docker/` and can not be removed
by changing the log tag templates.
The issue is that syslog driver hardcodes `path.Base(os.Args[0])`
as the prefix, which is the binary file name of the daemon (`dockerd`).
This could be an issue for certain situations (e.g., #22358) where
user may prefer not to have a dedicated prefix in syslog messages.
There is no way to override this behavior in the current verison of
the docker.
This fix tries to address this issue without making changes in the
default behavior of the syslog driver. An additional
`{{.DaemonName}}` has been introduced in the syslog tag. This is
assigned as the `docker` when daemon starts. The default log tag
template has also been changed from
`path.Base(os.Args[0]) + "/{{.ID}}"` to `{{.DaemonName}}/{{.ID}}`.
Therefore, there is no behavior changes when log-tag is not provided.
In order to be consistent, the default log tag for fluentd has been
changed from `docker.{{.ID}}` to `{{DaemonName}}.{{.ID}}` as well.
The documentation for log-tag has been updated to reflect this change.
Additional test cases have been added to cover changes in this fix.
This fix fixes#22358.
Signed-off-by: Yong Tang <yong.tang.github@outlook.com>
Since 1.9, driver specific log tag options
`syslog-tag`
`gelf-tag`
`fluentd-tag`
have been deprecated in favor of the generic tag
option which is standard across different logging
drivers.
This fix removed the deprecated driver specific
log tag options of `syslog-tag`, `gelf-tag`,
`fluentd-tag` for 1.12 and updated the docs.
Signed-off-by: Yong Tang <yong.tang.github@outlook.com>
This fix tries to add an additional syslog-format of `rfc5424micro` which follows
the same as rfc5424 except that it use microsecond resolution for timestamp. The
purpose is to solve the issue raised in #21793 where log events might lose its
ordering if happens on the same second.
The timestamp field in rfc5424 is derived from rfc3339, though the maximium
resolution is limited to "TIME-SECFRAC" which is 6 (microsecond resolution).
The appropriate documentation (`docs/admin/logging/overview.md`) has been updated
to reflect the change in this fix.
This fix adds a unit test to cover the newly introduced format.
This fix fixes#21793.
Signed-off-by: Yong Tang <yong.tang.github@outlook.com>
Previously docker used obsolete rfc3164 syslog format for syslog. rfc3164 explicitly
uses semicolon as a separator between 'TAG' and 'Content' section of the log message.
Docker uses semicolon as a separator between image name and version tag.
When {{.ImageName}} was used as a tag expression and contained ":" syslog parser mistreated
"tag" part of the image name as syslog message body, which resulted in incorrect "syslogtag" been reported by syslog
daemon.
Use of rfc5424 log format partually fixes the issue as it does not use semicolon as a separator.
However using default rfc5424 syslog format itroduces backward incompatability because rsyslog template keyword %syslogtag%
is parsed differently. In rfc3164 it uses the "TAG" part reported before the "pid" part. In rfc5424 it uses "appname" part reported
before the pid part, while tag part is introduced by %msgid% part.
For more information on rsyslog configuration properties see: http://www.rsyslog.com/doc/master/configuration/properties.html
Added two options to specify logging in either rfc5424, rfc3164 format or unix format omitting hostname in order to keep backwards compatability with
previous versions.
Signed-off-by: Solganik Alexander <solganik@gmail.com>
- downcase and privatize exported variables that were unused
- make accurate an error message
- added package comments
- remove unused var ReadLogsNotSupported
- enable linter
- some spelling corrections
Signed-off-by: Morgan Bauer <mbauer@us.ibm.com>
- noplog driver pkg for '--log-driver=none' (null object pattern)
- centralized factory for log drivers (instead of case/switch)
- logging drivers registers themselves to factory upon import
(easy plug/unplug of drivers in daemon/logdrivers.go)
- daemon now doesn't start with an invalid log driver
- Name() method of loggers is actually now their cli names (made it useful)
- generalized Read() logic, made it unsupported except json-file (preserves
existing behavior)
Spotted some duplication code around processing of legacy json-file
format, didn't touch that and refactored in both places.
Signed-off-by: Ahmet Alp Balkan <ahmetalpbalkan@gmail.com>
This patch changes two things
1. Set facility to LOG_DAEMON
2. Remove ": " from tag so that the tag + pid become a single column in
the log
Signed-off-by: Darren Shepherd <darren@rancher.com>