The jsonfilelog read benchmark was incorrectly reusing the same message
pointer in the producer loop. The message value would be reset after the
first call to jsonlogger.Log, resulting in all subsequent calls logging
a zero-valued message. This is not a representative workload for
benchmarking and throws off the throughput metric.
Reduce variation between benchmark runs by using a constant timestamp.
Write to the producer goroutine's error channel only on a non-nil error
to eliminate spurious synchronization between producer and consumer
goroutines external to the logger being benchmarked.
Signed-off-by: Cory Snider <csnider@mirantis.com>
This commit replaces `os.Setenv` with `t.Setenv` in tests. The
environment variable is automatically restored to its original value
when the test and all its subtests complete.
Reference: https://pkg.go.dev/testing#T.Setenv
Signed-off-by: Eng Zer Jun <engzerjun@gmail.com>
Some packages were using `logrus.Fatal()` in init functions (which logs the error,
and (by default) calls `os.Exit(1)` after logging).
Given that logrus formatting and outputs have not yet been configured during the
initialization stage, it does not provide much benefits over a plain `panic()`.
This patch replaces some instances of `logrus.Fatal()` with `panic()`, which has
the added benefits of not introducing logrus as a dependency in some of these
packages, and also produces a stacktrace, which could help locating the problem
in the unlikely event an `init()` fails.
Before this change, an error would look like:
$ dockerd
FATA[0000] something bad happened
After this change, the same error looks like:
$ dockerd
panic: something bad happened
goroutine 1 [running]:
github.com/docker/docker/daemon/logger/awslogs.init.0()
/go/src/github.com/docker/docker/daemon/logger/awslogs/cloudwatchlogs.go:128 +0x89
Signed-off-by: Sebastiaan van Stijn <github@gone.nl>
pkg/urlutil (despite its poorly chosen name) is not really intended as a generic
utility to handle URLs, and should only be used by the builder to handle (remote)
build contexts.
This patch:
- fix some cases where the host was ignored for valid addresses.
- removes a redundant use of urlutil.IsTransportURL(); instead adding code to
check if the given scheme (protocol) is supported.
- improve port validation for out of range ports.
- fix some missing validation: the driver was silently ignoring path elements,
but expected a host (not an URL)
Signed-off-by: Sebastiaan van Stijn <github@gone.nl>
fix some missing validation: the driver was silently ignoring path elements
in some cases, and expecting a host (not an URL), and for unix sockets did
not validate if a path was specified.
For the latter case, we should have a fix in the upstream driver, as it
uses an empty path as default path for the socket (`defaultSocketPath`),
and performs no validation.
Signed-off-by: Sebastiaan van Stijn <github@gone.nl>
pkg/urlutil (despite its poorly chosen name) is not really intended as a generic
utility to handle URLs, and should only be used by the builder to handle (remote)
build contexts.
This patch:
- removes a redundant use of urlutil.IsTransportURL(); instead adding some code
to check if the given scheme (protocol) is supported.
- define a `defaultPort` const for the default port.
- use `net.JoinHostPort()` instead of string concatenating, to account for possible
issues with IPv6 addresses.
- renames a variable that collided with an imported package.
- improves test coverage, and moves an integration test.
Signed-off-by: Sebastiaan van Stijn <github@gone.nl>
pkg/urlutil (despite its poorly chosen name) is not really intended as a generic
utility to handle URLs, and should only be used by the builder to handle (remote)
build contexts.
This patch removes the use of urlutil.IsURL(), in favor of just checking if the
provided scheme (protocol) is supported.
Signed-off-by: Sebastiaan van Stijn <github@gone.nl>
pkg/urlutil (despite its poorly chosen name) is not really intended as a generic
utility to handle URLs, and should only be used by the builder to handle (remote)
build contexts.
This patch:
- removes a redundant use of urlutil.IsTransportURL(); code further below already
checked if the given scheme (protocol) was supported.
- renames some variables that collided with imported packages.
Signed-off-by: Sebastiaan van Stijn <github@gone.nl>
This function is marked deprecated in Go 1.18; however, the suggested replacement
brings in a large amount of new code, and most strings we generate will be ASCII,
so this would only be in case it's used for some user-provided string. We also
don't have a language to use, so would be using the "default".
Adding a `//nolint` comment to suppress the linting failure instead.
daemon/logger/templates/templates.go:23:14: SA1019: strings.Title is deprecated: The rule Title uses for word boundaries does not handle Unicode punctuation properly. Use golang.org/x/text/cases instead. (staticcheck)
"title": strings.Title,
^
pkg/plugins/pluginrpc-gen/template.go:67:9: SA1019: strings.Title is deprecated: The rule Title uses for word boundaries does not handle Unicode punctuation properly. Use golang.org/x/text/cases instead. (staticcheck)
return strings.Title(s)
^
Signed-off-by: Sebastiaan van Stijn <github@gone.nl>
The log message's timestamp was being read after it was returned to the
pool. By coincidence the timestamp field happened to not be zeroed on
reset so much of the time things would work as expected. But if the
message value was to be taken back out of the pool before WriteLogEntry
returned, the timestamp recorded in the gzip header of compressed
rotated log files would be incorrect.
Make future use-after-put bugs fail fast by zeroing all fields of the
Message value, including the timestamp, when it is put into the pool.
Signed-off-by: Cory Snider <csnider@mirantis.com>
followLogs() is getting really long (170+ lines) and complex.
The function has multiple inner functions that mutate its variables.
To refactor the function, this change introduces follow{} struct.
The inner functions are now defined as ordinal methods, which are
accessible from tests.
Signed-off-by: Kazuyoshi Kato <katokazu@amazon.com>
* When async is enabled, this option defines the interval (ms) at which the connection
to the fluentd-address is re-established. This option is useful if the address
may resolve to one or more IP addresses, e.g. a Consul service address.
While the change in #42979 resolves the issue where a Docker container can be stuck
if the fluentd-address is unavailable, this functionality adds an additional benefit
in that a new and healthy fluentd-address can be resolved, allowing logs to flow once again.
This adds a `fluentd-async-reconnect-interval` log-opt for the fluentd logging driver.
Signed-off-by: Sebastiaan van Stijn <github@gone.nl>
Signed-off-by: Conor Evans <coevans@tcd.ie>
Co-authored-by: Sebastiaan van Stijn <github@gone.nl>
Co-authored-by: Conor Evans <coevans@tcd.ie>
Before this change, if Decode() couldn't read a log record fully,
the subsequent invocation of Decode() would read the record's non-header part
as a header and cause a huge heap allocation.
This change prevents such a case by having the intermediate buffer in
the decoder struct.
Fixes#42125.
Signed-off-by: Kazuyoshi Kato <katokazu@amazon.com>
The flag ForceStopAsyncSend was added to fluent logger lib in v1.5.0 (at
this time named AsyncStop) to tell fluentd to abort sending logs
asynchronously as soon as possible, when its Close() method is called.
However this flag was broken because of the way the lib was handling it
(basically, the lib could be stucked in retry-connect loop without
checking this flag).
Since fluent logger lib v1.7.0, calling Close() (when ForceStopAsyncSend
is true) will really stop all ongoing send/connect procedure,
wherever it's stucked.
Signed-off-by: Albin Kerouanton <albinker@gmail.com>
Added an option 'awslogs-format' to allow specifying
a log format for the logs sent CloudWatch from the aws log driver.
For now, only the 'json/emf' format is supported.
If no option is provided, the log format header in the
request to CloudWatch will be omitted as before.
Signed-off-by: James Sanders <james3sanders@gmail.com>
The io/ioutil package has been deprecated in Go 1.16. This commit
replaces the existing io/ioutil functions with their new definitions in
io and os packages.
Signed-off-by: Eng Zer Jun <engzerjun@gmail.com>
daemon/volumes_unix_test.go:228:13: SA4001: &*x will be simplified to x. It will not copy x. (staticcheck)
mp: &(*c.MountPoints["/jambolan"]), // copy the mountpoint, expect no changes
^
daemon/logger/local/local_test.go:214:22: SA4001: &*x will be simplified to x. It will not copy x. (staticcheck)
dst.PLogMetaData = &(*src.PLogMetaData)
^
Signed-off-by: Sebastiaan van Stijn <github@gone.nl>
daemon/logger/journald/read.go:128:3 comment on exported function `CErr` should be of the form `CErr ...`
daemon/logger/journald/read.go:131:36: unnecessary conversion (unconvert)
return C.GoString(C.strerror(C.int(-ret)))
^
daemon/logger/journald/read.go:380:2: S1023: redundant `return` statement (gosimple)
return
^
Signed-off-by: Sebastiaan van Stijn <github@gone.nl>
Logging to daemon logs every time there's an error with a log driver can be
problematic since daemon logs can grow rapidly, potentially exhausting disk
space.
Instead, it's preferable to limit the rate at which log driver errors are allowed
to be written. By default, this limit is 333 entries per second max.
Signed-off-by: Angel Velazquez <angelcar@amazon.com>
The underlying Loggers Close() function can be called with the the
run() goroutine still writing to the driver. This is causing the
fluentd-golang-logger to panic cause it doesn't defensively check
for the closing of the channel before writing to it.
It relies on the docker daemon to keep the contract of not calling Log()
if Close() has already been called.
Contributions by: James Johnston <james.johnston@thumbtack.com>
Nathan Wong <nathanw@thumbtack.com>
Signed-off-by: Anuj Varma <anujvarma@thumbtack.com>
Tonis mentioned that we can run into issues if there is more error
handling added here. This adds a custom reader implementation which is
like io.MultiReader except it does not cache EOF's.
What got us into trouble in the first place is `io.MultiReader` will
always return EOF once it has received an EOF, however the error
handling that we are going for is to recover from an EOF because the
underlying file is a file which can have more data added to it after
EOF.
Signed-off-by: Brian Goff <cpuguy83@gmail.com>
When the multireader hits EOF, we will always get EOF from it, so we
cannot store the multrireader fro later error handling, only for the
decoder.
Thanks @tobiasstadler for pointing this error out.
Signed-off-by: Brian Goff <cpuguy83@gmail.com>
Added an option `awslogs-create-stream` to allow skipping log stream
creation for awslogs log driver. The default value is still true to
keep the behavior be consistent with before.
Signed-off-by: Xia Wu <xwumzn@amazon.com>
Loggers that implement BufSize() (e.g. awslogs) uses the method to
tell Copier about the maximum log line length. However loggerWithCache
and RingBuffer hide the method by wrapping loggers.
As a result, Copier uses its default 16KB limit which breaks log
lines > 16kB even the destinations can handle that.
This change implements BufSize() on loggerWithCache and RingBuffer to
make sure these logger wrappes don't hide the method on the underlying
loggers.
Fixes#41794.
Signed-off-by: Kazuyoshi Kato <katokazu@amazon.com>
This fixes the case where log rotation fails on Windows while there are
clients reading container logs.
Evicts readers if there is an error during rotation and try rotation again.
This is needed for Windows with this scenario:
1. `docker logs -f` is called
2. Log rotation occurs (log.txt -> log.txt.1, truncate and re-open
log.txt)
3. Log rotation occurs again (rm log.txt.1, log.txt -> log.txt.1)
On step 3, before this change, the log rotation will fail with `Access
is denied`.
In this case, what we have is a reader holding a file handle to the
primary log file. The log file is then rotated, but the reader still has
a the handle open. `FILE_SHARE_DELETE` allows this to happen... but then
we try to do it again for the next rotation and it blows up.
So when it blows up we force all the readers to disconnect, close the
log file, and try rotation again, which will succeed based on the added
tests.
Signed-off-by: Brian Goff <cpuguy83@gmail.com>
This makes sure, on Windows, that all files are opened with
FILE_SHARE_DELETE.
On non-Windows this just calls the same `os.Open()`.
Signed-off-by: Brian Goff <cpuguy83@gmail.com>
- Ignore some pointless errors (like not exist on remove)
- Consolidate error handling/logging
- Fix race condition reading last log timestamp in the compression
goroutine. This needs to be done while holding the write lock, which
is not (or may not be) locked while compressing a rotated log file.
- Remove some indentation and consolidate mutex unlocking in
`compressFile`
Signed-off-by: Brian Goff <cpuguy83@gmail.com>